Chapter 1: Overview

34

Fiber Optic Port

and Transceiver

Slot LEDs

The 1000Base-SX fiber optic ports on the AT-9408LC/SP Switch and the
GBIC and SFP transceiver slots have one LED. The LED is defined in
Table 4.

Each 10 Gigabit Ethernet transceiver slot on the AT-9424Ts/XP and
AT-9448Ts/XP Switches has one LED, defined in Table 5.

Table 4 1000Base-SX Port and GBIC and SFP Slot LED

LED

Function

State

Description

L/A

Link Status
and Activity

Off

No link is established between the
port and the end node.

Solid
green

The port has established a link at
1000 Mbps.

Flashing
green

Packets are being received or
transmitted at 1000 Mbps.

Table 5 XFP Slot LED

LED

Function

State

Description

L/A

Link Status
and Activity

Off

No link is established between the
port and the end node.

Solid
green

The port has established a link at 10
Gbps.

Flashing
green

Packets are being received or
transmitted at 10 Gbps.