Installation

12

Planning the Installation

Be sure to observe the following guidelines when planning the installation of
your switch.

❑

The end-nodes connected to the twisted pair ports can operate at 10
Mbps or 100 Mbps and half or full-duplex. The switch uses Auto-
Negotiation to determine the correct speed and duplex mode for each
port.

❑

The end-nodes connected to the ports on the switch can be a network
adapter card, hub, repeater, router, or another switch.

❑

The twisted pair port cabling must be kept away from sources of
electrical noise, such as radios, transmitters, power lines, broadband
amplifiers electrical motors, and fluorescent fixtures.

❑

A twisted pair port using the Auto-Negotiation feature to configure
the Auto MDI/MDI-X. It configures itself automatically as MDI or
MDI-X when connected to an end-node. Either a straight-through or
crossover twisted pair cable can be used to connect a switch port to any
network device.

Refer to Table 3 for the cabling specifications for the twisted pair ports.

Table 3 10Base-T/100Base-TX Twisted Pair Port Cabling Specifications

Operating Mode

Twisted Pair Cable

Maximum Operating
Distance

10Base-T

Shielded or Unshielded Category 3 or better

100 m (328 ft)

100Base-TX

Shielded or Unshielded Category 5 or better

100 m (328 ft)