31

Planning the Installation

This section describes the cables necessary for the
installation of an AT-iMG606BD Multiservice Gateway.

LAN Ports

Table 4 contains the cabling specifications for the LAN
ports.

Note

The twisted pair ports on the gateway feature auto-
MDI when operating at either 10 or 100 Mbps. Each
port is individually configured as MDI or MDI-X when
connected to an end node. Consequently, you can use
either a straight-through or crossover twisted pair
cable when connecting any network device to a
twisted pair port on the gateway.

Fiber Optic

Uplink Port

For cable and operating specifications for the fiber optic
uplink port, refer to “100Base-FX Fiber Optic Uplink (WAN)
Port” on page 47.

Console Port

The console port has an eight-pin DIN connector. To order
the AT-RGCONSOLECABLE-00 management cable,
contact your Allied Telesyn sales representative.

Table 4. Twisted Pair Cabling and Distances

Speed

Type of Cable

Maximum

Operating

Distance

10 Mbps

Category 3 or better 100-ohm unshielded
twisted pair cable

100 m (328 ft)

100 Mbps

Category 5 or Category 5E (Enhanced) 100-
ohm unshielded twisted pair cable

100 m (328 ft)