Phase 2, Phase 3 – Allied Telesis AT-S24 User Manual
Page 118

Configuring Virtual LANs and Quality of Service
118
Phase 2
Now that you have defined the new Accounting VLAN, you must
reconfigure the existing VLANs by removing the untagged ports that
you have assigned to the new Accounting VLAN. To accomplish this,
perform the following procedure:
1. From the Omega Main Menu, select Virtual LAN/QoS.
2. From the Virtual LAN/QoS menu, select Virtual LAN Definition.
3. Select the Default VLAN.
The VLAN window for the Default VLAN is displayed. In our example,
the Accounting VLAN is the first VLAN to be created on the switch.
Consequently, all ports by default are still members of the Default
VLAN. Thus, this is the VLAN that needs to be modified since it
contains the ports that are to be a part of the new VLAN.
4. Select the All Ports on VLAN field and change the entry from:
ALL
to
7-24
The reason for the change is because ports 1 to 6 are now untagged
members of the new Accounting VLAN and should no longer be
members of the Default VLAN. Select Enter or press <Return>.
5. Return to the Omega Main Menu.
Phase 3
The final phase is to change the PVID of the untagged ports in the new
VLAN to match the VID of the Accounting VLAN. To accomplishment
this, perform the following procedure:
1. From the Omega Main Menu, select Virtual LAN/QoS.
2. Select Port to VLAN configuration.
A window is displayed that lists each port on the switch and the VLAN
whose VID matches the port’s PVID. Figure 57 on page 115 is an
example of the window. The example shows that the PVID for all of
the ports are the switch match the VID of the Default VLAN and, thus,
that they all belong to the Default VLAN
3. Select port 1.
4. The management program displays a list of the VLANs on the switch.