Indesit K6G210SX-G User Manual

Page 5

Advertising
background image

GB

5

V

 The hob burners do not require primary air adjustment.

 After adjusting the appliance so it may be used

with a different type of gas, replace the old rating

label with a new one that corresponds to the new

type of gas (these labels are available from

Authorised Technical Assistance Centres).

 Should the gas pressure used be different (or vary

slightly) from the recommended pressure, a suitable

pressure regulator must be fitted to the inlet hose in

accordance with current national regulations relating

to “regulators for channelled gas”.

Adapting the oven

Replacing the oven burner nozzle

1. open the oven door fully

2. pull out the sliding oven

bottom

3. unscrew the burner

fastening screws

4. remove screw “V” and then

the oven burner;

5. Unscrew the oven burner

nozzle using the special

socket spanner for the

nozzles, or a 7 mm socket

spanner, and replace it with a

nozzle suited to the new type

of gas (see Table 1).

Take particular care

handling the spark plug wires and the

thermocouple pipes.

6. Replace all the parts, following the steps

described above in the reverse order..

Adjusting the gas oven burner’s minimum setting:
1. Light the burner (see Start-up and Use).

2. Turn the knob to the minimum position (MIN) after

it has been in the maximum position (MAX) for

approximately 10 minutes.

3. Remove the knob.

4. Tighten or loosen the adjustment screws on the

outside of the thermostat pin (see figure) until the

flame is small but steady.

 If the appliance is connected to liquid gas, the

adjustment screw must be fastened as tightly as

possible.

5. Turn the knob from the MAX position to the MIN

position quickly or open and shut the oven door,

making sure that the burner is not extinguished.

Adapting the grill

Replacing the grill burner nozzle:

1. Remove the oven burner

after loosening screw V (see

figure).

2. Unscrew the grill burner

nozzle using a special nozzle

socket spanner (see figure) or

preferably with a 7 mm socket

spanner, and replace it with a

new nozzle that is suited to the

new type of gas (see Burner

and nozzle specifications table).

 Be careful of the spark plug wires and the

thermocouple tubes.

 The oven and grill burners do not require primary

air adjustment.

 After adjusting the appliance so it may be used

with a different type of gas, replace the old rating

label with a new one that corresponds to the new

type of gas (these labels are available from

Authorised Technical Assistance Centres).

 Should the gas pressure used be different (or vary

slightly) from the recommended pressure, a suitable

pressure regulator must be fitted to the inlet hose in

accordance with current national regulations relating

to “regulators for channelled gas”.

V

I

Advertising
This manual is related to the following products: