Operation

15

F232088

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Cycle Selection

The push button cycle selector switch on the control
module provides a selection of four complete
automatic cycles. See the table below for more
information.

Press the START button to start the selected cycle.

Mechanical Timer Cycles

Step

Time

(Min)*

Water Level

Program Water Temperature

White

Permanent

Press

Colors

Bright Colors

Prewash

2

High

Warm

Warm

Cold

Cold**

Drain

1

Auxiliary Heat Wash Step Temperature †

194 °F / 90 °C

140 °F / 60 °C

104 °F / 40 °C

86 °F / 30 °C

Wash

4

Low

Hot

Warm

Warm

Cold

Drain

1

Extract

0.5

Rinse 1

1.5

High

Cold

Cold

Cold

Cold

Drain

1

Extract

0.5

Rinse 2

1.5

High

Cold

Cold

Cold

Cold

Drain

1

Extract

0.5

Rinse 3

1.5

High

Cold

Cold

Cold

Cold

Drain

1

Extract

4

Shakeout

0.5

*Cycle times are for the factory-preset jumper configuration and do not include fill and heat times. See the Programming
section for more information.
**Auxiliary heat-equipped models only. Standard models do not have a prewash step in the Bright Colors cycle.
†Auxiliary heat-equipped models only.