2. Electrical Service Specifications
a. Gas Models and Steam Models ONLY
IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models contact the
factory.
IMPORTANT:
The dryer
must be connected to the electric supply shown on the data label that is
affixed to the backside of the upper control door. In the case of 208 VAC or 230/
240 VAC, the supply voltage must match the electric service specifications of the
data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
MLG-55 (Gas)
MLS-55 (Steam)
E
LECTRIC
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact
voltage.
NOTES:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-Phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
CIRCUIT
BREAKER
60 Hz
50 Hz
120
1ш
2
12
---
*
25
208
1ш
2
7.1
---
*
15
230/240
1ш
2
6.5
---
*
15
208
3ш
3/4
3.1
---
*
15
230/240
3ш
3/4
3.1
3.7
*
15
380/400
3ш
3/4
---
2.2
*
15
416
3ш
3/4
---
2.3
*
15
460/480
3ш
3/4
2
---
*
15
*
AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
(Motor lead type wire is recommended.)