background image

31

4. Steam Damper Air System Connections

The MLS-55 is manufactured with a pneumatic (piston) damper system which requires an external supply
of compressed air. The air connection is made to the steam damper solenoid valve, which is located at the
rear inner top area of the dryer just in front of the electric service relay box.

a. Air Requirements

b. Air Connection

Air connection to system -- 1/8-inch N.P.T.

c. No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.52

bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the
compressed air line just before the dryer connection. This is necessary to insure that correct and clean
air pressure is achieved.

C

OM P RESSED

A

IR

S

UPP LY

A

IR

P

RESSURE

Normal

80 PSI

5.52 bars

Minimum Supply

70 PSI

4.83 bars

Maximum Supply

90 PSI

6.21 bars

Shaded areas are stated in metric equivalents