ROTHENBERGER ROFROST TURBO 1.1/4 und 2 User Manual

Page 18

Advertising
background image

14

ENGLISH

4) Power tool use and care

a) Do not force the power tool. Use the correct power tool for your application. The

correct power tool will do the job better and safer at the rate for which it was designed.

b) Do not use the power tool if the switch does not turn it on and off. Any power

tool that cannot be controlled with the switch is dangerous and must be repaired.

c) Disconnect the plug from the power source before making any adjustments,

changing accessories, or storing power tools. Such preventive safety measures
reduce the risk of starting the power tool accidentally.

d) Store idle power tools out of the reach of children and do not allow persons

unfamiliar with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.

e) Maintain power tools. Check for misalignment or binding of moving parts,

breakage of parts and any other condition that may affect the power tools
operation. If damaged, have the power tool repaired before use.
Many accidents
are caused by poorly maintained power tools.

f) Use the power tool, accessories and tool bits etc., in accordance with these

instructions and in the manner intended for the particular type of power tool,
taking into account the working conditions and the work to be performed.
Use of
the power tool for operations different from those intended could result in a hazardous
situation.

5) Service

Have your power tool serviced by a qualified repair person using only identical replacement
parts. This will ensure that the safety of the power tool is maintained.

1.3

Safety information

Regulations
EN 60335-1: 2007

BGR 500 Teil2.35

EN 60335-2-24: 2009

DIN EN 378:2008

EN 60335-2-34: 2009

DIN EN 60721-3-7:1995

What to do in the event of accidents or disruptions in the refrigerating system

Danger
Please comply in full with the following safety information in order to exclude personal
injuries
!

Shutting down in emergencies
Î

Immediately ensure the system power is off by:

Pulling out the plug

Switching off the fuse

Refrigeration cycle intervention
Î

Only allowed by refrigeration technical experts. Contact customer service.

Î

Take care in the event of accumulation of cooling agent vapours at ground level – lack of

oxygen – risk of suffocation!

Î

Smoking and unshielded flames prohibited!

Î

Always ensure the power is off in the system before intervention (see above)!

First aid
Î

Use protective goggles to shield your eyes against exposure to liquid cooling agents!

In the event of eye contact with liquid cooling agent do not rub the eyes and avoid all eye

aggravation. Consult a physician immediately.

Advertising