Variety steamer, Troubleshooting (continued) – A.J. Antunes & Co VS-200ADB 9100230 User Manual

Page 15

Advertising
background image

15

Variety SteaMer

P/N 1010649 Rev. G 03/12

A.J. Antunes & Co.

trOUblesHOOtInG (continued)

problem

possible cause

corrective action

unit heats but there is little

or no steam produced

and/or

the product requires more

steaming than usual.

(Continued)

insufficient or excessive calcium/mineral

buildup on Generator surface.

Verify that a thin layer of calcium/min-

eral deposits is present on the Generator

surface. Refer to the Maintenance section

of this manual.

black Manifold O-ring is worn, damaged,

or missing.

Replace the black Manifold O-ring if worn,

damaged, or missing.

Low Generator temperature.

Verify Generator surface temperature is at

least 380°F (193°C),

steam leaks out of the

sides of the unit.

black Manifold O-ring is damaged or

missing.

Replace the black Manifold O-ring if worn,

damaged, or missing.

black Manifold is difficult

to remove or reinstall onto

the Generator.

black Manifold not being removed and

cleaned daily as required.

Remove and clean the black Manifold daily

according to the Maintenance section of

this manual.

black Manifold O-ring is damaged or

worn.

Replace the black Manifold O-ring if dam-

aged or worn.

black Manifold O-ring is not being

lubricated daily with Petro-Gel.

Lubricate the black Manifold O-ring daily

according to the Maintenance section of

this manual.

unit floods overnight

and/or continues to steam

even when just in ready

mode.

solenoid valve is being held open by

debris from the building’s water line

piping.

NOte: Verify that there is a pre-strainer/

filter on the water line just before the unit.

attempt to flush the debris out of the valve

by running the unit on a number of cycles

and then letting it rest. if the unit still

leaks, contact your maintenance person or

authorized service agency.