Variety steamer, Installation (continued), A.j. antunes & co – A.J. Antunes & Co VS-200ADB 9100230 User Manual

Page 8

Advertising
background image

8

Variety SteaMer

P/N 1010649 Rev. G 03/12

A.J. Antunes & Co.

Connect Quick

Disconnect

Insert Here

Front Legs

Raised

Slightly

Quick

Disconnect

Insert

Connect Black

Drain Hose Here

Inlet Hose &

Strainer Assy.

(Supplied)

Water Pressure Regulator

& Strainer Assy. P/N 7000314

(Not Supplied)

Shut Off Valve

(Not Supplied)

Cold

Water

Flow

Flexible Nylon Braided

1/4 " I.D. Tubing (Not Supplied)

warnInG

be sure to follow all guidelines, procedures, and

precautions listed in the important safety informa-

tion section of this manual.

figure 2. connecting water supply

plUmbInG

nOte: Variety steamer models are designed to

use cold tap water.

this unit requires a direct water hookup. a Water inlet

Hose and Strainer Assembly (Figure 2) are supplied.

1. Turn off the Water Valve (not supplied) that pro-

vides water to the unit (Figure 2).

2. Connect the 1/4” I.D. flexible tubing to the outlet

side of the Water Pressure Regulator and secure

with the Worm Clamp (Figure 2).

nOte: a water pressure regulator (p/n 7000314)

must first be installed (figure 2). failure to do so

will result in poor steaming and possible flooding.

3. turn on the Water Valve.
4. Hold the Quick Disconnect Insert over a bucket,

then press and hold the white plastic tip until

there’s a good, steady water flow. this will purge

all air out of the line.

caUtIOn

this equipment is to be installed to comply with

the basic plumbing code of the building Officials

and code administrators, Inc. (bOca) and the

food service sanitation manual of the food and

Drug administration (fDa).

5. Release the plastic tip and check the pressure on

the Water Pressure Regulator Gauge. it should

read 20 psi.

a.) If it reads less, increase the water pressure by

pulling the black knob up and turning it clockwise.

b.) If it reads more, decrease the water pressure

by pulling the black knob up and turning it counter

clockwise.

nOte: when adjusting the knob, you must relieve

the existing pressure by pressing the white plastic

tip on the Quick Disconnect insert for 3 seconds.

the gauge will then show the new pressure.

6. Once the gauge reads 20 psi, push the black

knob down to lock it in place.

7. Push the Quick Disconnect Insert into the fitting

at the rear of the unit until it clicks (Figure 2).

nOte: Incoming water is controlled by a solenoid

valve inside the electrical housing of the steamer.

8. Connect the Black Drain Hose to the Drip Tray

(Figure 2). Place the other end of the hose in a

drain or collection pan.

caUtIOn

water pressure must not exceed 30 psi (2.1

kg/cm2 or 207 kpa). Higher water pressure

may cause poor performance or flooding. to

reduce water pressure, install a water pressure

regulator, and set the pressure between 20–25 psi

(1.4–1.7 kg/cm2 or 138–172 kpa). to order a water

pressure regulator from your authorized service

agency, order roundup p/n 7000314.

InstallatIOn (continued)

Advertising