Variety steamer (vs-250), Maintenance (continued) – A.J. Antunes & Co VS-200A-A1 9100250 User Manual

Page 10

Advertising
background image

VAriety SteAMer (VS-250)

10

P/N 1010591 Rev. E 03/12

A.J. Antunes & Co.

maIntenance (continued)

monthly cleaning

nOte: frequency of cleaning is determined by

water conditions, usage, and water filter systems.

1. Perform all steps of the Daily Cleaning but do

NOt reinstall all removed parts.

2. after cleaning the Needle Plate, use a suitable

1/16” punching tool (such as a large paper clip) to

clear all needle holes of mineral deposits.

3. Remove the Diffuser Plate from the Generator.

4. Remove the spray tube by lifting it and pulling it

free of the generator.

5. check the inside of the spray tube for mineral

deposits. if deposits have formed, carefully flex

the tube so the deposits crumble and fall out,

making sure not to create any sharp bends in the

tube.

6. if deposits are still present, soak the spray tube

overnight in a vinegar solution to dissolve the

remaining deposits.

nOte: If vinegar is used, be sure to wash the spray

tube in detergent water and rinse well before rein-

stalling in the unit.

7. check the water ports of the spray tube for min-

eral deposits. if they are clogged, remove them

with the end of a paper clip.

nOte: some mineral deposits must be present on

the Generator to ensure proper steaming. If during

cleaning the Generator becomes free of deposits,

they will reform as the unit is used.

8. Reinstall the Spray Tube and Diffuser.

9. Lightly apply some Petro gel (supplied) onto the

O-ring and then reinstall the O-ring.

10. Reinstall the Needle Plate and lock it in place by

pulling the Lock Lever Knob towards the front of

the unit. check that the plate is securely locked in

place.

11. Reconnect the water hose and plug in the power

cord.

cleaning steam chamber

1. turn the power off, unplug the power cord, and

allow the unit to cool for approximately 30

minutes.

2. Remove the Needle Plate and soak in a mineral

dissolver (ex. vinegar or delimer).

3. Remove the O-ring and set aside.

4. Pour mineral dissolver onto the generator, filling

it 1/4” to the top.

5. allow the generator to soak for one hour or more,

depending on the amount of buildup.

6. carefully empty mineral dissolver from generator

and wipe up any spills in the unit.

7. Remove Diffuser Plate and Spray Tube.

8. Remove Needle Plate from mineral dissolver.

9. Wash Diffuser Plate, Spray Tube, and Needle

Plate in soap and hot water and then rinse in

clear water.

10. use a paper clip to clear all needle holes of any

mineral deposit.

11. Wipe down the generator with a hot, damp cloth

to remove any remaining mineral dissolver.

12. Plug in the power cord and turn the unit on. Wait

approximately 20 minutes for the unit to warmup.

13. Press the MOMENtaRY switch three times

to purge any remaining dissolver from the

generator.

14. turn the power off, unplug the power cord, and

allow the unit to cool down.

14. Lightly apply Petro gel onto the O-ring and

reinstall on the generator Manifold.

15. Reinstall all remaining parts.

16. clean entire unit with a hot, damp cloth and wipe

dry.

nOte: Do nOt use a dripping wet cloth. wring it

out before use.

16. Plug the power cord back in and return to service.

Advertising