VAriety SteAMer (VS-250)

P/N 1010591 Rev. E 03/12

A.J. Antunes & Co.

cautIOn

this equipment is to be installed to comply with

the basic plumbing code of the building Officials

and code administrators, Inc. (bOca) and the

food service sanitation manual of the food and

Drug administration (fDa).

unpacking

1. Remove unit and all packing materials from

shipping carton.

2. the unit should contain the following:

• Owner’s Manual

• Authorized Service Agency Directory

• Petro Gel Tube

• Inlet Hose and Strainer Assembly

• Black Drain Tubing

nOte: If any parts are missing or damaged,

contact antunes technical service ImmeDIately

at 1-877-392-7854 or 630-784-1000.

3. Remove all packing materials and protective

coverings.

4. Remove and wash the Needle Plate, O-ring, and

Diffuser (Figure 1) in soap and water. Rinse with

clean hot water and allow to air dry.

5. Wipe all surfaces of the unit with a hot damp

cloth.

nOte: Do nOt use a dripping wet cloth. wring

out before use.
6. Reinstall all removed parts.

plumbing

nOte: Variety steamer models are designed to

use cold tap water at 20–25 psi (1.4–1.7 kg/cm2 or

138–172 kpa).

1. connect the water supply hose to the Quick

Disconnect Body on the rear of the unit.

2. connect the other end of the water supply hose

to the water supply.

3. turn on the water supply.
4. Disconnect the water supply hose from the

unit by pressing down on the tab on the Quick

Disconnect Body.

5. Hold the Quick Disconnect Insert over a bucket,

and press and hold the white plastic tip until

there’s a good, steady water flow.

6. Push the fitting back into the Quick Disconnect

until it clicks into place.

7. connect the other end of the water supply hose

to the Quick Disconnect Body on the rear of the

unit.

InstallatIOn

equipment setup

1. Place the unit on a sturdy, level table or other

work surface. be sure the power is off before

proceeding.

2. connect the unit to the power supply.
3. Connect the Black Drain Tubing to the Drip Tray

by pressing the tubing onto the drain pipe at the

bottom of the Drip Tray.

4. Place the other end of the tubing in a drain or

collection pan.

5. Rotate the black rubber tips on the front legs so

the unit is tilted slightly to the rear.

6. turn the power on and allow 20 minutes for the

unit to warmup.

nOte: Do nOt operate the unit during the warmup

period. this could cause flooding in the unit.
7. Press and release the Momentary switch on the

front panel to clear air out of the water line.

8. turn off the power and allow the unit to cool.

cautIOn

water pressure must not exceed 30 psi (2.1

kg/cm2 or 207 kpa). Higher water pressures

may cause poor performance or flooding. to

reduce water pressure, install a water pressure

regulator, and set water pressure to 20–25 psi

(1.4–1.7 kg/cm2 or 138–172 kpa).

figure 1. wash Items

O-ring

Diffuser

needle plate

Advertising