8 trouble shooting, 9 order numbers – A.J. Antunes & Co HRS-200 9700562 User Manual

Page 12

Advertising
background image

12

US

ERROR

CAUSE

ACTION

water supply out of the

filter is stopped

Water supply in general is

stopped or a valve is close

Open and check all the valves

Filter cartridge is not mounted

properly in the filter head

Loosen the filter cartridge by turning the filter

cartridge 180 degree clockwise and tighten the

filter cartridge again (see chapter 6.9)

Wrong mounted filter head

Check the flow direction of the water accor-

ding the arrow (see chapter 6.5.2), change the

flow direction if necessary

Low flow rate

System pressure is too low

Check the system pressure (see chapter 6.2)

Integrated shut-off in the

filter head is leaking

(while the filter cartridge

is removed)

Particles within the integrated

shut-off

Rinse the system with installed filter

(see chapter 6.8)

Screw connection bet-

ween the fitting is leaking

Sealing is defect

Check the sealing, if necessary replace the

sealing

Air bubbles

System isn’t purged completely

Repeat the purging/rinsing process

(see chapter 6.8)

turbid/white water

generation of small bubbles of

carbon acid

After 5 minutes the turbidity is vanished

completely

Heater, boiler are not en-

ough protected against

lime scale

wrong chosen blend setting, filter

capacity is reached/passed, filter

size is too small

Check the hardness blend setting and the

filter capacity, if necessary use the bigger size

of the filter cartridge

8 Trouble Shooting

Order Number

Filter Head w/ Bracket

2180373

Replacement cartridge VIZION HRS-100

7000966

Replacement cartridge VIZION HRS-200

7000967

9 Order Numbers

Checking the hoses/piping

regular inspection, hoses/piping should not be squeezed or bent,
replace squeezed/bent hoses/piping

Shut down

After a shut down of more than two days the cartridge has to be
rinsed with at least 1.1–1.3 US gallons (4-5 Litres) of water

Replacement of the
filter cartridge

at least after 12 months independent of the remaining capacity,
also after a shut down of more than 4 weeks

Replacement of the filter head after 5 years

Replacement of the hoses

after 5 years

NOTE!

f

Note, that the filter has to be changed within the given period and capacity otherwise there is the
risk of health.

f

Filter heads and hoses older than 5 years may cause damage of property, change accordingly.

Advertising