1 scope of delivery, 2 technical data – A.J. Antunes & Co HRS-200 9700562 User Manual

Page 3

Advertising
background image

3

US

1 Scope of Delivery

1.1 Installation Set
The installation set consists of the following parts (see Fig. 1):

 

Filter head (1) with female thread for the connection to the filter cartridge. The head is fitting to
different VIZION HRS filter cartridge sizes. An integrated shut-off and two non return valve (inlet
and outlet) are installed in the filter head

 

Wall bracket (2) to mount the filter cartridge

 

Filter cartridge (HRS-100 and HRS-200) (3) with hygienic cap and male thread as counterpart to
the filter head (1)

 

Installation and Operating Manual
For hygienic reasons all parts are wrapped in a protection foil.

1.2 Replacement Cartridge
The replacement package includes a VIZION HRS filter cartridge with a protection/hygienic cap (3)
wrapped in a protection foil including the installation and operation manual.

2 Technical Data

2.1 Dimensions and Weights

VIZION HRS

100

200

Total height without wall mounting bracket (A)

Inch

Inch

(mm)

19.30-19.69

19

5/16

– 19

11/16

(490 – 500)

22.44-22.83

22

7/16

– 22

13/16

(570 – 580)

Total height with wall monuting bracket (B)

Inch

Inch

(mm)

20.87

20

7/8

(530)

23,62

23

5/8

(600)

Height to centre of connection (C)

Inch

Inch

(mm)

17.72

17

11/16

(450)

20.47

20

7 /16

(520)

Distance required for service (D)

Inch

Inch

(mm)

2.56

2

9/16

(65)

2.56

2

9/16

(65)

Installation length (E)

Inch

Inch

(mm)

4.93

4

15/16

(125)

4.93

4

15/16

(125)

Filter cartridge Ø (F)

Inch

Inch

(mm)

5.71

5

11/16

(145)

7.28

7

1 /4

(185)

Filter cartridge weight, cartridge dry appr.

lb

(kg)

8.38

(3.8)

16.53

(7.5)

Filter cartridge weight, wet appr.

lb

(kg)

13.23

(6.0)

24.25

(11.0)

Advertising
This manual is related to the following products: