InstallatIOn (continued)

Drain Valve connection

The drain line is for flushing particle buildup out of the

system during self cleaning. When connecting the drain

line, pay attention to the following guidelines:
• The drain line plumbing must be able support the

flow rate whenever the system flushes. This flow

rate is dependent on the inlet water pressure, inlet

pipe size, and system.

• The drain line leading out of the system must be

as short as possible and slope downwards without

any kinks or loops.

• The drain line plumbing must be position and

secured at least 2 inches above the drain (Figure

3). This air gap protects the system from contami-

nation in the event of a backed-up drain.

• The drain used must not be blocked or restricted.

• The drain used must be as large or larger than

the drain line plumbing.

permeate line plumbing

To ensure the highest quality and safest water, it is

recommended that a check valve (to prevent backflow)

be installed in the water line after the permeate connec-

tion. This will help prevent possible contamination of the

filter system due to other equipment downstream. The

check valve (not supplied) should be mounted close to

the system outlet, and sized properly for the plumbing

line. Check with local codes for the proper specification.
A shutoff valve (not supplied) should be installed in the

filtered water line leading from the system. The valve

should be mounted close to the system outlet and sized

properly for the plumbing line. This valve will allow for

easier servicing and future cartridge replacement.

figure 3. proper Drain plumbing

2” (5.1 cm)

minimum

2” (5.1 cm)

minimum

floor

Drain

secure

end

Drain line

from system

Drain line

from system

secure

end

Drain

standpipe

starting the controller

1. Select the proper AC plug for your electrical outlet

and install it onto the power supply.

2. Plug the appropriate end of the power cord into

the controller.

3. Plug the other end of the power cord into the electri-

cal outlet. The leDs on the controller will light up.

4. The controller automatically enters Flush Mode

and the Flush leD starts to flash.

5. When flushing is complete, the Flush leD will

stop flashing and one or more leDs will remain lit,

indicating the unit has power and which interval is

selected in the controller.