Uf-216cc water filtration system, Installation (continued), A.j. antunes & co – A.J. Antunes & Co UF-216CC 9700407 User Manual

Page 11

Advertising
background image

UF-216CC water Filtration system

11

A.J. Antunes & Co.

P/N 1011135 Rev. A 03/12

InstallatIOn (continued)

rinsing the ultra filter cartridge

The Ultra Filter Cartridge must be rinsed before the sys-

tem is used to remove any air and protective solution.
nOte: ultra filter cartridge must be rinsed to drain

before use. rinsing to drain removes storage solu-

tion and air. Do nOt rinse into carbon if present.

carbon life and/or performance may be affected.

nOte: make sure the carbon block cartridge is

nOt installed in the carbon Housing.

1. Direct water from the Permeate Outlet to a drain.
2. Open the tap or faucet closest downstream to the

filter system.

3. Slowly open the inlet water valve and allow water

to enter the system.

4. Press the

flusH button. The Drain Valve will

open and air and water will come out of the drain

line. Repeat six times to ensure all air and stor-

age solution are flushed out of the Ultra Filter

Cartridge.

5. Allow water to continue to run through the system

and out the faucet for 15 minutes.

6. Inspect the unit for any leaks and repair as

needed.

7. After 15 minutes with water flow, close the tap or

faucet and let the system stand without water flow

for 15 minutes to allow trapped air to come out of

the hollow fibers of the Ultra Filter Cartridge.

8. After 15 minutes without water flow, open the tap

or faucet for five minutes to flush out the trapped

air.

9. Close the tap or faucet.
10. Press the

flusH button to open the Drain Valve.

Repeat six times to ensure any remaining air is

flushed out of the system.

sanitizing the system and lines

The plumbing must be sanitized to eliminate possible

contamination that may have occurred during the instal-

lation process.
One ounce (30 ml) of liquid chlorine bleach (regular

bleach, unscented 6% sodium hypochlorite) can be

used to sanitize the plumbing. The amount of bleach

needed depends on the system and the amount of

plumbing downstream of the system.
nOte: follow the handling and safety instructions

supplied with the bleach.
1. Follow the steps in the

rinsing the Ultra Filter

Cartridge in the Installation section of this manual.

2. Turn off the water to the system.
3. Open the faucet or tap closest downstream to the

system.

4. Close the Inlet Water Valve and allow the system

to depressurize.

5. Place a bucket under the “T” or cross fitting at the

inlet connection to the system. Open the inlet drain

valve or unscrew the cap to drain the system.

6. Press the

flusH button to help drain the system.

7. When the water flow out of the inlet fitting stops,

close the inlet drain valve and pour the liquid

bleach into the inlet connection fitting. Be careful

not to spill bleach onto clothing or skin. You may

want to add the bleach using a cup. Reattach the

cap on the fitting.

8. Slowly open the inlet water valve and allow water

to flow out of the tap until the smell of bleach is

present.

9. Immediately close the tap and let the system

stand with no water flow for at least 15 minutes to

allow the bleach to sanitize the pipes.

10. After 15 minutes without water flow, open the tap

and flush until the presence of bleach is gone. All

other taps should be opened to flush any bleach

from the plumbing. Close the taps.

11. Press the

flusH button to complete the flushing

process.

Advertising