TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Unit does not have power.

The power cord is not plugged into the

appropriate outlet or control box.

Plug power cord into the appropriate outlet.

The unit is plugged into a switched

electrical outlet.

Plug the power cord into an unswitched outlet.

Universal Pulse Controller is inoperable.

Contact your maintenance person or Authorized

Service Agency.

Transformer is defective.

No water comes out of the

filter system.

Inlet/Outlet Ball Valves closed.

Open the Inlet/Outlet Ball Valves.

System depressurized.

Pressurize system.

Drain Valve is stuck open.

Clean, rebuild, and/or replace the Drain Valve.

Rinse Ball Valve is open.

Close the Rinse Ball Valve.

The system may be in a flush cycle.

Wait for the flush cycle to end.

Inlet Strainer (if installed) is plugged.

Clean or replace Inlet Strainer

Ultra Filter Cartridge is plugged.

Replace Ultra Filter Cartridge.

Low water flow comes out of the

filter system.

See above.

See above.

The inlet water pressure is too low.

Boost the inlet water pressure.

The inlet flow restrictor may be plugged.

Clean or replace the inlet flow restrictor.

Water tastes bad.

Storage/shipping solution not completely

flushed out of the system.

Flush the system for a longer period of time;

replace Carbon Element.

Biological growth in pipes.

Sanitize plumbing.

Water condition changed.

Consider installing additional filtration.

Broken capillaries in Ultra Filter

Cartridge.

Replace Ultra Filter Cartridge.

Flush runs continuously.

Drain Valve stuck open.

Clean, rebuild, or replace the Drain Valve.

Controller sending continuous signals to

valve.

Replace the controller.

Flush runs too long.

Flush settings changed from factory

setting.

Confirm flush settings; change back to

factory settings.

Inoperable Universal Pulse Controller.

Replace the Universal Pulse Controller.

Flush occurs at a time of high

water usage.

The controller interval is set incorrectly or

setting was lost due to power loss.

Set interval.

Water splashes at drain during

flush.

Drain line not positioned properly.

Reposition the end of the drain line.

Drain not capable of handling high flow

rate.

Clean drain; find alternate drain.

Water leaks at ends of the Ultra

Filter cartridge after changing

cartridge.

O-ring not lubricated.

Lubricate O-ring with food grade lubricant.

O-ring is split, cut, or twisted.

Replace O-ring.

Water leaks from system

fitting or connection.

Fitting broken or loose.

Tighten or replace the fitting.

Not enough pipe thread sealant used.

Redo the fitting with the proper amount of seal-

ant.