Vzn series, Operation – A.J. Antunes & Co VZN-440H 9700746 User Manual

Page 8

Advertising
background image

VZN SERIES

8

P/N 1011064 Rev. F 12/13

OPERATION

CAUTION

Changing the flush interval can cause the Ultra Filter to

plug prematurely and may reduce the life of the filter.

Consult the factory for more information.

Ultra Filtration

Cartridge

System

Flush

Solenoid

Valve

(Automatic)

Outlet

Inlet

Figure 1. System Components

Overview

The VZN system operates in two modes:

Normal Operation Mode

Flush Mode

During Normal Operation Mode, water enters the Inlet and

flows through the Ultra Filter before exiting the Permeate

Outlet as usable product water.

During Flush Mode, the Drain Valve opens and water enter-

ing the Inlet flushes and cleans the Ultra Filter membrane by

removing any debris collecting on the membrane wall.

The Drain Valve is only powered during Flush Mode.

NOTE: Do NOT unplug the power cord or turn off the sys-

tem during Flush Mode. If there is a power outage or the

system is unplugged, water will continue to be filtered

but the system will NOT flush. This could cause the Ultra

Filter to plug prematurely and may reduce the life of the

filter.

The flush is automated by the Universal Pulse Controller to

last 10 seconds and take place in one-hour intervals. This

interval can be changed (see

Changing the Interval Setting

in the Maintenance section of this manual).

Manual Flushing

A manual flush can be activated at any time by pressing the

FLUSH button on the Universal Pulse Controller.

When the

FLUSH button is pressed, the Flush LED on the

controller flashes and the Drain Valve opens for 10 seconds.

After flushing is complete, the Drain Valve will close, the Flush

LED will stop flashing and the unit will automatically return to

Normal Operation Mode.

NOTE: A manual flush will not affect the interval flush

setting.