A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

1-630-784-1000 Fax: 630-784-1651

Page 3 of 4

P/N 1011091 06/10

1-800-253-2991

Assembly

1. Remove bracket and insulator from unit.

2. Place TTC unit through panel cut-out.

3. Place insulator on TTC unit and attach bracket.

NOTE: Bracket is not to touch metal surface of panel.

Bracket must rest on insulator. Any other method of

mounting will cause damage to the internal operation of

the TTC unit.

Sold State Replay Output

When the temperature seen by the thermocouple

is above the set point, there will not be any voltage

between - and + terminals. If the temperature seen by the

thermocouple is below the set point, there will be 12‒16

VDC output. This output is capable of providing 30 mA.

If an “open” thermocouple condition occurs, the voltages

between - and + terminals will be zero.

Set Point Calibration and Output States

If transformers other than those supplied by Antunes

Controls are used, the transformer colors/leads and

power capabilities may not be the same.

If field calibration is required, a two-point calibration

with a millivolt generator can be used. Allow 30 minutes

for the unit to stabilize before calibrating. Calibrate the

low reading by adjusting the zero pot. Enter the second

calibration higher than the first point and adjust the span.

Recall these two points if needed.

When the button on the lower left of the unit is pushed in

and held, the set point is displayed. As long as the button

is held in, the set point is displayed. When the button is

out, the temperature at the thermocouple is displayed.

The knob on the lower right is used to change the set

point. Turn the knob clockwise to increase the set point.

Turn the knob counter clockwise to decrease the set

point.

The diagram above shows the output states of the

controller internal relay when the temperature as seen by

the thermocouple is above or below the set point. Make

the connection accordingly observing the power rating

of the contacts. The unit will read “EEE” for over range

inputs. If the thermocouple “opens”, the internal relay will

go its “not operated” state.

NC

NC

NC

Temperature over

setpoint, relay not

operated

Temperature under

setpoint, relay operated

NC

NC

NC

TTC Installation Information