Electrical Wiring-Combination Models
Electrical Wiring-Single Models
Model: HLGP-A
Duty: High Low Gas Reset Switch
Elec. Rating: 10A, 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Indicator On
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Reset lever will latch
when gas pressure is
below setting
High Gas
NO
C
By Others
R e s e t
HLGP-A
Reset lever will latch
when gas pressure is
above setting
Indicator Off
C
Low Gas
NC
By Others
NO
Model: RHLGP-A
Duty: High Low Gas Reset Switch
Elec. Rating: 10A, 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Indicator On
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Contacts C & NC
break when pressure
rises
above setting
High Gas
NO
C
By Others
R e s e t
RHLGP-A
Contacts C & NO
make when pressure
rises
above setting
Indicator Off
C
Low Gas
NC
By Others
NO
Model: HGP-A
Duty: High Gas Reset Switch
Elec. Rating: 10A, 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Indicator On
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Reset lever will latch
when gas pressure is
below setting contact
C & NC make
NC
NO
C
By Others
R e s e t
H G P - A
Model: LGP-A
NC
NO
C
By Others
Reset lever will latch
when gas pressure is
above setting contact
C & NO make
R e s e t
L G P - A
Duty: Low Gas Reset Switch
Elec. Rating: 10A, 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Indicator Off
Model: RHGP-A
Duty: High Gas Recycle Switch
Elec. Rating: 10A, 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Indicator On
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Contacts C & NC
break when pressure
rises above setting
NC
NO
C
By Others
Recycle
RHGP-A
Model: RLGP-H
NC
NO
C
By Others
Contacts C & NO
make when pressure
rises above setting
Recycle
RLGP-A
Duty: Low Gas Recycle Switch
Elec. Rating: 10A: 1/8 HP, 125 VAC
5A, 1/4 HP, 250 VAC
Pilot Duty: 125 VA, 125-250 VAC
Field wiring to be rated @75ºC for max 120ºF Ambient
Field wiring to be rated @90ºC for max 140ºF Ambient
Max Surge Pressure: 10 PSIG
Indicator Off