5. DMX-512 Control Connection

Connect an XLR cable to the female 5-pin XLR output of your Elektralite CP 20 or other DMX
controller. The other end should be connected to the male 5-pin XLR input of the Elektralite 1018

(5-in-1)

. Then daisy-chain out of the first Elektralite 1018 (5-in-1) into the next Elektralite 1018

(5-in-1)

or other dmx device. Never “Y” split the DMX connection.

If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and
output connector. Please refer to the diagram below.

1

2

3

4

5


DMX-512 connection with DMX terminator

For installations where the DMX cable has to run a long distance or is in an electrically “noisy”
environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the
digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 Ω resistor
connected between pins 2 and 3. It is then plugged into the output XLR socket of the last Elektralite

1018

(5-in-1) or other dmx device in the chain. Please see illustration below.

1

2

3

4

5

Ω

120