21

Channel 12 – Lamp on/off, reset, internal

0-19

color change normal by direction depend on distance

20-39

color change to any position by direction depend on distance

40-59 Lamp

on

60-79

Lamp switch off

80-99 Motor

reset

100-119

Internal program 1

120-139

Internal program 2

140-159

Internal program 3

160-179

Internal program 4

180-199

Internal program 5

200-219

Internal program 6

220-239

Internal program 7

240-255

Internal program 8

Channel 13 – Pan fine

Channel 14 – Tilt fine


ERROR MESSAGE

When you turn on the fixture, it will reset first. The display may show “Xer” while there are problems with one or
more channels. “XX” stands for channel 1,2,3,5,6,7 which has the testing sensor for positioning .
So, for example, when the display shows “02Er”, it means there is some error in channel 2. If there are errors
on channel 1, channel 2, channel 5 at the same time, you will see the error message “01Er”, “02Er”,”05Er” flash
repeated for 5 times. Then the fixture will generate a reset signal to all the stepper motors. If the error message
remains after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors.

01Er:

Color wheel error. This message will appear after resetting MY 250 and the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive circuit
on the main circuit board). Normally after a reset, the color wheel will go to its default position.

02Er:

Rotating gobo wheel error. This message will appear after resetting MY 250 and the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive circuit
on the main circuit board). Normally after a reset, the rotating gobo wheel will go to its default position.

03Er:

Rotating gobo indexing error. This message will appear after resetting MY 250 and the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive
circuit on the main circuit board). Normally after a reset, the rotating gobo will go to its default position.

04Er:

Fixed gobo wheel error. This message will appear after resetting MY 250 and the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive circuit
on the main circuit board). Normally after a reset, the fixed gobo wheel will go to its default position

05Er:

Pan movement error. This message will appear after resetting MY 250 and the yoke’s magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive IC on
the main circuit board). Normally after a reset, the yoke will go to its default position.