Condensor installation (outdoor), 2) drain elbow installation – Alen AMS12 12000 BTU AND 13.5 SEER User Manual

Page 12

Advertising
background image

CONDENSOR INSTALLATION (OUTDOOR)

Install the outdoor unit on a rigid base to prevent increasing noise level and
vibration. Determine the air outlet direction where the discharged air is not
blocked.


In the case that the installation place is exposed to strong wind place the
unit lengthwise along the wall or use dust or shield plates.

If need suspended installation, the installation bracket should accord with
technique requirement in the installation bracket diagram. The connection
between bracket and wall, bracket and the air conditioner should be firm,
stable and reliable.

Be sure there is no obstacle which blocks the air flow.

Install the unit on a flat, level surface where is can be fastened securely.

1) Condensor (Outdoor) Unit Installation Precaution

Strong wind

2) Drain Elbow Installation

Fit the seal into the drain elbow, then insert
the drain elbow into the base pan hole of the
condensor (outdoor) unit, rotate 90

o

to securely

assemble. Connect the drain elbow with an
extension drain hose (locally purchased), in case
the water drains off the condensor (outdoor) unit
during the heating mode. (heating models only).

Seal

Drain Elbow

Base pan hole of

condensor

(outdoor) unit

Seal

Drain Pipe

11

Advertising