4. Output Connections (VertX EVO V2000) –

All Output connections are used for general purpose controls. The following
table shows where the various outputs are located. Pin numbers shown use the
convention “NO/C/NC”. For example, Output 1, V2000: P3 Pin 1 is NO
(Normally Open,) Pin 2 is C (Common,) and
Pin 3 is NC (Normally Closed).
Note: Relays are dry contact rated for 2Amps @ 30VDC, resistive.

Output
number

V2000

1

P3 Pins 1/2/3

Strike(lock) Relay 1

2

P3 Pins 4/5/6

Aux Relay 1

3

P6 Pins 6/5/4

Strike (lock) Relay 2

4

P6 Pins 3/2/1

Aux Relay 2

CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high
instantaneous break voltage when de-energized due to magnetic field collapse. Use a snubber circuit
across the controlling relay terminals to protect the controlling relay contacts. Go to

support.hidglobal.com

, see Solution 891 - How do I wire a High In-Rush Current locking device to

VertX/Edge/Edge Solo?.