Accessories, Troubleshooting – Karcher KM 120-150 R Bp 2SB User Manual

Page 32

Advertising
background image

-

13

Î

Check tension of drive belt and V-belt of
the suction blower, also check for wear
or damage.

Figure 26

Î

Check tension of drive belt and V-belt of
the roller brush also check for wear or
damage.

Figure 27

Î

Chek the cup seal at the suction blower
regularly to see that it sits properly.

Î

Turn main key to "0" and remove it.

Î

Remove side brush.

Figure 28

Î

Remove splash guard (1).

Î

Disconnect plug (2).

Î

Twist contact plate to one side (3).

Î

Remove defective bulb (4).

Î

Insert new bulb.

Î

Twist contact plate back into original
position.

Î

Connect plug.

Î

Mount splash guard.

Î

Screw on side brush.

Figure 29

* covered by A2
The operator may only replace the follow-
ing vehicle flat fuses having the following
values:
– 7.5 A (F1) – Fuse - CPU module head.
– 20 A (F6) – Fuse - accessories module.
– 50 A (F5) – Fuse - hydraulic pump.
– 15 A (F8) – Fuse - left side brush (op-

tional).

– 10 A (F7) – Fuse - filter cleaning module

(optional).

The drive control/electronic system is in-
stalled behind the front panel. To replace a
fuse, the front panel must be removed.
Î

Loosen screws on both sides of the
panel.

Note
The assignment of fuses is indicated on the
inside of the front panel. Only use fuses
with identical safety ratings.
Î

Replace defective fuses.

Î

Replace front panel.

Figure 30

Î

Replace defective fuse.

Note
Defective pole fuses may only be replaced
by a Kärcher service technician or an au-
thorised expert. If these fuses are defec-
tive, then check the usage conditions and
the entire control system.

Figure 31

Î

Remove suction hose from holder.

Î

Suck in the dirt.

Î

Insert the suction hose in the holder.

Note
After completing the suction, ensure that
the tube of the suction hose lies on the floor
of the holder.

ƽ

Danger

Risk of injury! Before carrying out any tasks
on the machine, set the main key to "0" and
remove it. Press emergency-stop button.
In case of faults that cannot be remedied
using the table below please contact the
customer service.

The display shows the existing faults at in-
tervals of 4 seconds.
Example:
– Fault driving function F1/022
If the faults continue to be displayed on the
console even after 4 seconds, then pro-
ceed as follows:
Î

Release emergency-stop button.

Î

Set the key switch to "0" (switch off the
machine).

Î

Wait till the text on the display has dis-
appeared.

Î

Set the main switch again to "1" (switch
on the machine). Carry out the trouble-
shooting measures in the given se-
quence only if the fault occurs again. At
such times, always bring the main
switch to the "0" position and ensure
that the emergency-stop button is de-
pressed.

Î

If the fault cannot be repaired, call cus-
tomer service and quote the fault
code(s) (F1/022 in the example).

Check cup seal

Replacing electric bulb

Replacing fuses

Pole fuses

Accessories

Installation set suction hose

Troubleshooting

Fault indication

32

EN

Advertising