Storage, Maintenance and care, Troubleshooting – Karcher IVL 120-27-1 User Manual

Page 14: Motor (suction turbine) does not start, Suction capacity decreases slowly, Emptying the liquid container is taking very long, Indicator lamp "mains voltage" is on, Customer service, Storage maintenance and care troubleshooting

Advertising
background image

– 5

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Rinse the appliance and the accesso-
ries with fresh water at regular intervals
and let them dry.

In order to avoid bacteria, do not leave
the chips and liquids inside the appli-
ance.

During extended operation breaks,
open the cover to let the residual mois-
ture escape.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

ƽ

Danger

Have all checks and works on electrical
parts performed by an expert.

Liquid container filled.

Empty the liquid container.

No electrical voltage.

Check the receptacle and the fuse of
the power supply.

Check the power cable and the power
plug of the device.

Protective motor switch was triggered.

Reset switch.

Swimmer switch blocked.

Clean swimmer switch.

Nozzle, suction hose or suction pipe
may be blocked.

Check, clean accessories.

Drain hose valve not fully closed.

Close the drain valve, clean if neces-
sary.

Backflow valve in the connecting stub
for accessories is contaminated or de-
fective.

Check backflow valve, clean if neces-
sary.

Drain hose crushed or obstructed.

Check the drain hose and the valve,
clean if necessary.

The mains plug is plugged in and the mains
voltage is applied.

Suction turbine rotates in the wrong di-
rection; interchange poles at the plug.

If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.

Storage

Maintenance and care

Troubleshooting

Motor (suction turbine) does not

start

Suction capacity decreases slowly

Emptying the liquid container is tak-

ing very long

Indicator lamp "mains voltage" is

on

Indicator lamp "direction of rotation

incorrect" is on (IVL 120/30 only)

Customer Service

14

EN

Advertising
This manual is related to the following products: