Device elements symbols on the machine, Safety instructions – Karcher NT 35-1 Tact Te H User Manual

Page 18

Advertising
background image

– 2

After using the asbestos suction device
in a cordoned off area in the sense of
TRGS 519, the asbestos suction device
should no longer be used in the so-
called white area. Exceptions are possi-
ble if the asbestos suction device has
first been decontaminated totally by an
expert (not only the external cover but
also the cooling room, installation room
for electrical components, the compo-
nents themselves, etc.) according to the
specifications of TRGS 519 No. 2.7.
This is to be documented and signed by
the expert.

This appliance is suited for the commer-
cial use, e.g. in hotels, schools, hospi-
tals, factories, shops, offices, and rental
companies.

1 Electrodes
2 Suction hose
3 Cable hook
4 Air outlet, working air
5 Suction head lock
6 Wheel
7 Air inlet, motor cooling air
8 Suction head
9 Steering roller
10 Dirt receptacle
11 Suction support
12 Connection bushing
13 Floor nozzle
14 Suction tube
15 Rotary switch for suction hose cross

section

16 Carrying handle
17 Filter cover
18 Filter cover screw
19 Scale of the suction hose cross section
20 Bender
21 Rotary switch for suction output (min-max)
22 Indicator lamp
23 Socket
24 Automatic filter dedusting
25 Main switch
26 Flat fold filter

27 Filter dedusting
28 Floor nozzle holder
29 Holder for crevice nozzle
30 Holder for suction pipes
31 Power cord
32 Nameplate

ƽ

Danger

When the outgoing air is carried back
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V

R

x ventilation rate L

W

) at maxi-

mum. Without a specific ventilation
system the following applies: L

W

=1h

–1

.

Only persons trained in the use of the
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.

This appliance contains harmful dust.
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.

Do not use the appliance without the
complete filtering system.

Please follow the safety regulations ap-
plicable to the materials that are to be
treated.

Device elements

Symbols on the machine

Flat fold filter
Order No.

6.904-242.0

Safety filter bag
Order No.

6.904-266.0

Safety instructions

18

EN

Advertising