Karcher HDS 7-16 4C Basic User Manual

Page 30

Advertising
background image

– 10

Water shortage

Check water supply, check connec-
tions.

Leak in the high pressure system

Check high pressure system and con-
nections for tightness.

Fault in the voltage supply or current
pickup of the motor too high.

Check main connections and mains
fuse.

Inform Customer Service

Engine overload/overheat

Set the appliance switch to "0/OFF“.

Allow device to cool down.

Turn on the appliance.

Error occurs repeatedly.

Inform Customer Service

The exhaust temperature limiter has
been triggered.

Set the appliance switch to "0/OFF“.

Allow device to cool down.

Turn on the appliance.

Error occurs repeatedly.

Inform Customer Service

Obstructed reed switch in the lack of
water fuse or magnetic piston stuck.

Inform Customer Service

The flame sensor turned the burner off.

Inform Customer Service

Fuel tank empty.

Refill fuel.

No power

Check power connection/conduit.

Air within the system

Vent pump:

Set dosing value for detergent to "0".

With open hand spray gun turn device
on and off multiple times with the device
switch.

Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.

Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.

If detergent tank is empty, refill.

Check connections and conduits.

Pressure is set to MIN

Set pressure to MAX.

Sieve in the water connection is dirty

Clean sieve.

Clean the fine filter; replace it, if neces-
sary.

Amount of water supply is too low.

Check water supply level (refer to tech-
nical data).

Pump leaky

Note: 3 drops/minute are allowed.

With stronger leak, have device
checked by customer service.

Leak in the high pressure system

Check high pressure system and con-
nections for tightness.

Indicator lamp service

1x blinking

2x blinking

3x blinking

4x blinking

5 x blink

6 x blink

Fuel indicator lamp glows

Appliance is not running

Device is not building up pressure

Device leaks, water drips from the

bottom of the device

Device turns on and off while hand

spray gun is closed

30