Actiontec electronic IS560LH User Manual

Page 66

Advertising
background image

66

S1

Ring Counter

Range:

0

255

Default:

0

Units:

rings

This register, Ring Counter, is read only. The value of S1 is incremented with each
ring. If no rings occur over a six second interval, this register is cleared.

S2

AT Escape Character (user defined)

Range:

0

255

Default:

43

Units:

ASCII

This register determines the ASCII valued used for an escape sequence. The default is
the + character. The escape sequence allows the modem to exit data mode and enter
command mode when on-line. Values greater than 127 disable the escape sequence.

S3

Command Line Termination Character (user defined)

Range:

0

127, ASCII decimal

Default:

13 (carriage return)

Units:

ASCII

This register determines the ASCII values as the carriage return character. This char-
acter is used to end command lines and result codes.

S4

Response Formatting Character (user defined)

Range:

0

127, ASCII decimal

Default:

10 (line feed)

Units:

ASCII

This register determines the ASCII value used as the line feed character. The modem
uses a line feed character in command mode when it responds to the computer.

S5

Command Line Editing Character (user defined)

Range:

0

32, 127

Default:

8 (backspace)

Units:

ASCII

This register sets the character recognized as a backspace and pertains to asynchro-

Advertising