2 enquiry answer (complete), 3 enquiry answer (command cancel), 4 error answer – Sony FWD-50PX2 User Manual

Page 6

Advertising
background image

2

FWD-50PX2

(c) Answer (Display

Response to Host)

1 Control answer

No. Item

Value

1

Header

0x70: Answer

2

Answer

*

0x00: Completed

0x01: Limit Over

0x02: Limit Under

0x03: Command Canceled

3

Check Sum 0xXX

*

0x00: Completed

Normal response.

0x01: Limit Over

The packets was received normally, but the
data value was over the upper limit.
Forcedly the monitor adjusted the data to
maximum value.

0x02: Limit Under

The packets was received normally, but the
data value was under the lower limit.
Forcedly the monitor adjusted the data to
minimum value.

0x03: Command Canceled The packets was received normally, but the

command was cancelled because the function
was not in adjustable mode, such as “

_

” a

function displayed as in user menu.

*

Check Sum:

The total from No.1 to No.2, when value
exceeds 255, 1byte of data is confirmed the
bottom.

2 Enquiry answer (Complete)

No. Item

Value

1

Header

0x70: Answer

2

Answer

0x00: Completed

3

Return Data Size 0xXX

4

Return Data1

0xXX

:

:

0xXX

:

:

0xXX

X

Return DataX

0xXX

X

+

1 Check Sum

0xXX

*

0x00: Completed Normal response.

*

Return Data returns the read value.

*

Check Sum: The total from No.1 to No.X, when value exceeds 255,1byte

of data is confirmed the bottom.

3 Enquiry answer (Command cancel)

No. Item

Value

1

Header

0x70: Answer

2

Answer

0x03: Command Canceled

3

Check Sum

0xXX

*

0x03: Command Canceled The packets was received normally, but the

command was cancelled because the function
was not in adjustable mode, such as “

_

” a

function displayed as in user menu.

*

Check Sum:

The total from No.1 to No.2, when value
exceeds 255, 1byte of data is confirmed the
bottom.

4 Error answer

No. Item

Value

1

Header

0xE0: Answer

2

Answer

*

0x00: No Function Error

0x01: Check Sum Error

0x02: Data Length Error

3

Check Sum

0xXX

*

0x00: No Function Error Packet header, category of function codes do not

exist in this protocol.

0x01: Check Sum Error The “Check Sum” value of the packet which

received is wrong.

0x02: Data Length Error The “Data Num” value of the packet which

received is wrong.

Advertising