Error/warning indications, Error indications, Warning indications – Sony FDR-AX1 User Manual

Page 61: Error indications warning indications

Advertising
background image

Error/Warning Indications

61

Ap
pend

ic

es

The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the LCD/viewfinder screen, the recording lamp, and a buzzer.
The buzzer is output to the headphones connected via the headphone connector.

The camcorder stops operation after the following indications.

When one of the following indications is generated, follow the message to resolve the problem.

Error/Warning Indications

Error indications

Error indication on
LCD/viewfinder

Buzzer

Recording
lamp

Cause and measures

C:04:ss

The battery pack is not an “InfoLITHIUM” battery pack. Use
an “InfoLITHIUM” battery pack (page 54).

C:06:ss

The battery pack temperature is high. Change the battery
pack or place it in a cool place.

C:32:ss

Remove the power source. Reconnect it and operate your
camcorder again.

E:20:ss/E:40:ss/
E:41:ss/E:50:ss/
E:51:ss/E:61:ss/
E:62:ss/E:92:ss/
E:94:ss/E:95:ss

Perform the following steps.
1 Check the list, and inspect your camcorder.
2 Disconnect the power source, attach the power source again

after about 1 minute, and turn the camcorder on.

3 Contact your Sony dealer or local authorized Sony service

facility.

Warning indications

Warning indication
on LCD/viewfinder

Buzzer

Recording
lamp

Cause and measures

Media Near Full

Intermittent

Flashing

Free space on the XQD memory card has become
insufficient.
Replace it with another at the earliest opportunity.

Media Full

Continuous

Rapidly
flashing

No space is left on the XQD memory card. Recording, clip
copying and clip division cannot be performed.
Replace it with another.

Battery Near End

Intermittent

Flashing

The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.

Battery End

Continuous

Rapidly
flashing

The battery pack is discharged. Recording cannot be
performed.
Stop operation and change the battery pack.

Battery Temperature
High
Turn Power Off

The temperature of the battery pack has risen above a safe
operation limit.
The camcorder turns off automatically.

Temperature High

Intermittent

Flashing

The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.

Battery Error
Please Change Battery

An error was detected with the battery pack.
Replace the battery pack with a normal one.

Advertising