The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.

When a warning indicator other than the above starts flashing, consult with Sony Customer
Information Service Center.

Warning Indicators

Symptom

Cause and Remedy

LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)

c Close the lamp cover securely, then tighten the screws securely.

(

1 page 57)

c Close the filter holder securely. (1 page 59)

LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)

c The lamp has reached the end of its useful lifespan. Replace the

lamp. (

1 page 57)

c The lamp has reached a high temperature. Wait until the lamp

cools, and then turn on the power again.

ON/STANDBY flashes in
red. (A repetition rate of 4
flashes)

c The fan is broken. Consult with qualified Sony personnel.

ON/STANDBY flashes in
red. (A repetition rate of 2
flashes)

c The internal temperature is unusually high. Check to ensure that

if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.

ON/STANDBY flashes in
red. (A repetition rate of 6
flashes)

c Disconnect the AC power cord, then confirm the ON/STANDBY

lamp is turned off. Turn on the power again after re-connecting it.
If the indicators still light up, the electrical system has a problem.
Consult with qualified Sony personnel.