Sony VPL-VW50 User Manual

Page 59

Advertising
background image

59

Oth

e

rs

9

Attach the new air filter so that it
fits into the each claws (10
positions) on the filter holder.

Attach the Air Filter aligning it with the
shape of the filter holder.
Also, do not touch the fan after removing
the air filter that is set deep inside the
projector.

10

Attach the filter holder.

11

Wipe dust off the Ventilation
holes (intake) with a soft cloth.

The projector will not turn on unless the
filter holder is securely closed.

12

Place the project back on its
original position.

13

Turn on the projector, then
select the desired setting item
on the Setup

menu. The

menu screen below will be
appeared.

14

Select “Yes”.

15

Select “OK”.

Do not put your hands into the lamp
replacement slot, and do not allow any liquid
or other objects into the slot to avoid
electrical shock or fire.

• Be sure to use an LMP-H200 Projector Lamp

for replacement. If you use lamps other than
the LMP-H200, the projector may
malfunction.

• Be sure to turn off the projector and unplug

the power cord before replacing the lamp,
then check the ON/STANDBY lamp has
already been turned off.

• The projector will not turn on unless the lamp

is securely installed in place.

• The projector will not turn on unless the lamp

cover are securely closed.

• To cancel a message displayed on the screen,

press either the button on the remote control
or the one on the control panel on the
projector.

Note

Note

Ventilation holes (intake)

Caution

Notes

Note

The lamp contains mercury. The disposal
rules for used fluorescent tubes depend on
where you live. Follow the waste disposal
policy in your area.

Advertising