To Test Thermostat

WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS

VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL
DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.

CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE

IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR
CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY.

1. Place the EMER-HEAT-OFF-COOL switch into

the COOL position. The

will be displayed.

2. Press the

button until the temperature

setting is at least 3 degrees below the room
temperature. The air conditioning system should turn on within a
few seconds.

NOTE: ONCE THE THERMOSTAT TURNS OFF WHEN IN THE COOL MODE,

A BUILT IN 5-MINUTE DELAY PREVENTS THE SYSTEM FROM
TURNING ON AGAIN. THIS PROTECTS THE COMPRESSOR. NO
ADDITIONAL TIME DELAY RELAY IS REQUIRED. TO OVERRIDE THE
5-MINUTE DELAY FOR INSTALLATION, PRESS THE RESET BUTTON.

3. Put the EMER-HEAT-OFF-COOL switch into the

OFF position. The air conditioning system
should turn off.

4. Put the EMER-HEAT-OFF-COOL switch into the

HEAT position. The will be displayed.

5. Press the

button until the temperature

setting is at least 3 degrees above room
temperature. The heating system should turn on. The fan may
not turn on immediately, depending on the fan delay built into
the furnace.

NOTE: If HP is selected, the heat will not come on until the 5 minute

short cycle protection has expired.

6. Put the EMER-HEAT-OFF-COOL switch into the

EMER position. The

will be displayed.

7. Press the

button until the temperature

setting is at least 3 degrees above room
temperature. The secondary heating system should turn on.
NOTE: The compressor will not turn when in emergency heat mode.

8. Put the EMER-HEAT-OFF-COOL switch into the

OFF position. The heating system should turn
off. The fan may continue to run for a short
period of time.

9. Put the

AUTO-ON switch into the ON position.

The blower fan should turn on. The display will
show a

.

10. Put the

AUTO-ON switch into the AUTO position.

The blower fan should turn off.