Fitting procedure, Installing the wall-hanging bracket on the wall, Loosely tightening the screw for securing the unit – Panasonic TYWK42PV20 User Manual

Page 14: English

Advertising
background image

14

English

3. Installing the wall-hanging bracket on the wall

Determine the positions of the wall mounting holes based on the external dimensions drawings (see pages 83

and 84), and attach the bracket to the wall.

Horizontal installation Attach the wall-hanging bracket with the arrows facing up.

Vertical installation Attach the wall-hanging bracket with the direction indicated by “L” at the top.
• When the plasma display is installed vertically, be careful because the center position of the plasma display

will differ from the center position of the bracket due to the structure of the wall-hanging bracket.

Use screws or nuts with a nominal diameter of 6 mm (0.2 inches) to firmly secure the bracket at all of the six

mounting hole positions.

Notes

• For the wall mounting screws, use commercially available screws with a nominal diameter of 6 mm (0.2 inches) that are suited

to the material/structure to which you are fitting the bracket.

• Check the strength of the mounting screws. Use screws that are sufficiently strong.
• If you are embedding the screws, make sure they protrude from the wall surface by 10 to 15 mm (0.4 to 0.6 inches).
• Anchor the screws in at least six locations.

Fitting procedure

4. Loosely tightening the screw for securing the unit

Insert the screw for securing the unit into the base left or right fitting and loosely tighten it (turn it two or three
times).

Horizontal installation : Screw holes at bottom of side of base left and right fittings

Vertical installation : Screw holes at top and bottom of left side of fitting

(Select and use the hole that will make it easier for you to install the plasma display.)

Horizontal installation

Vertical installation

550 (21.7)

485 (19.1)

450 (17.8)

300 (1

1.9)

61.5

(2.5)

440 (17.4)
400 (15.8)

40 (1.6)

40 (1.6)

550 (21.7)

485 (19.1)
450 (17.8)

300 (11.9)

90.5

(3.6)

400 (15.8)

187.5 (7.4)

Screw for securing

unit (short)

(Bracket base

left fitting)

L

Unit: mm (inches)

Arrows

Screw for
securing unit
(long) 

Unit: mm (inches)