Fitting procedure, Fit wall-hanging bracket to wall, Angle adjustment of wall-hanging bracket – Panasonic TYWK42PR4W User Manual

Page 4: English

Advertising
background image

4

English

Fitting procedure

[ Never use any other method

than specified to install.]

1. Confirm the strength of the proposed fitting location.

(1) The weight of the wall-hanging bracket is approximately 10 kg (22.0 lbs). For the weight of

the plasma TV attached to the wall-hanging bracket, please see manual for the plasma TV.

(2) Check the wall strength at the 6 attachment locations by referring to the dimension drawing

of the wall-hanging bracket (given at right), and provide adequate reinforcement if strength

is not sufficient.

Notes

• There are 16 holes in the wall-hanging bracket.

If the wall material is wood, and adequate attachment
strength cannot be ensured by fastening at the 6 points at
right, use as many spare holes as necessary. However,
exercise care because some wall materials may crack if
screws are located too close together.

• For detailed dimensions for attaching the plasma TV, refer to

the separate External Dimension Drawing (page 46-50).

• Do not attach or place anything other than the plasma TV on

the bracket.

416 (16.4)

810 (31.9)

230 (9.1)

490 (19.3) 450 (17.7)

20 (0.8)

20 (0.8)

390 (15.4)

390 (15.4)

15

(0.6)

15

(0.6)

130 (5.1)

Unit: mm (inches)

* Be sure to fit screws and tighten securely.

Wall attachment
holes (at 6 points)

2. Fit wall-hanging bracket to wall.

(1) Fit so that the arrow marks on the wall-hanging bracket point upward.
(2) Fasten the screw at the top center hole (A) first.
(3) Using a level, correct any bracket inclination, and then fasten screws at the

remaining 5 locations.

Notes

• If the wall consists of a material such as concrete, and bolts or nuts must be

embedded beforehand, determine the hole positions using the actual wall-hanging
bracket, or calculate hole positions based on the dimension drawing and then embed
bolts or nuts with a nominal diameter of 6 mm. When embedding bolts, locate so that
the bolts protrude from the wall by 10 to 15 mm (25/64 to 19/32 inches).

• Use commercially available screws with a nominal diameter of 6 mm that are

suited to the wall material you are fitting the bracket to.

• Always fix firmly more than 6 places with a screw.

3. Angle adjustment of wall-hanging bracket.

The angle of the wall-hanging bracket can be adjusted from “no incline” to “20° incline” in 5 settings at intervals of 5°.
The bracket is set to 5° before shipment from the factory.
To change the angle, move the attachment position of the strap.

Note

• The strap is not required for the ‘no incline’ setting. Store the

strap and the attaching screws in a safe place (as they will be
needed for the inclined settings.)

The bolt should be securely tightened to the torque given
below.
(11 - 13 N•m)

At 5° incline

Strap

Strap

At 15° incline

No incline

W

all surface

W

all surface

W

all surface

Angle adjustment hole positions

5° incline

10° incline

15° incline

20° incline

No incline

TY-WK42PR4W_TQZH993-3_4048.indb 4