Alto-Shaam 1000-S User Manual

Page 13

Advertising
background image

1.

An identification tag is permanently mounted on

the cabinet.

2.

Plug cabinet into a properly grounded receptacle

ONLY, positioning the unit so the power supply cord

is easily accessible in case of an emergency.
Arcing will occur when connecting or disconnecting

the unit unless all controls are in the “OFF” position.

3.

If necessary, a proper receptacle or outlet

configuration as required for this unit, must be

installed by a licensed electrician in accordance with

applicable, local electrical codes.

For 230V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in

close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection against

potential difference. The terminal is marked with the

following symbol.

NOTE:

230V appliances must be connected to an electrical

circuit that is protected by an external GFCI outlet.

E L E C T R I C A L

I N S T A L L A T I O N

500-S, 750-S, 1000-S, 1000-UP • INSTALLATION/OPERATION/SERVICE MANUAL • 12.

E L E C T R I C A L - 5 0 0 - S

VOLTAGE

PHASE CYCLE

/

HZ AMPS

kW

CORD

&

PLUG

120

(

AGCY

)

1

60

8.3

1.0

NEMA

5-15

P

,

120

1

60

8.4

1.0

15A-125

V PLUG

208-240

(

AGCY

)

1

60

4.2

1.0

NEMA

6-15

P

,

at 208

1

60

3.7

.76

15A-250

V PLUG

at 240

1

60

4.2

1.0

(USA ONLY)

230

(

AGCY

)

1

50

4.1

.95

CEE

7/7,

230

1

50

4.0

.93

220-230

V PLUG

ELECTRICAL - 1000-S

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

K

W

CORD

&

PLUG

120

(

AGCY

)

1

60

8.0

.96

NEMA

5-15

P

,

120

1

60

8.6

1.03

15A-125

V PLUG

208-240

(

AGCY

)

1

60

4.0

.96

NEMA

6-15

P

,

at 208

1

60

3.7

.78

15A-250

V

at 240

1

60

4.3

1.03

PLUG (

USA ONLY

)

230

(

AGCY

)

1

50

3.8

.88

CEE

7/7,

230

1

50

4.1

.95

220-230

V PLUG

ELECTRICAL - 1000-UP

VOLTAGE

PHASE CYCLE

/

HZ AMPS

kW

CORD

&

PLUG

120

(

AGCY

)

1

60

16.0

1.9

NEMA

5-20

P

,

120

1

60

16.0

1.9

20A-125

V PLUG

208-240

(

AGCY

)

1

60

8.6

2.1

NEMA

6-15

P

,

at 208

1

60

7.4

1.6

15A-250

V PLUG

at 240

1

60

8.6

2.1

(

USA ONLY

)

230

(

AGCY

)

1

50

8.3

1.9

CEE

7/7,

230

1

50

8.2

1.9

220-230

V PLUG

E L E C T R I C A L - 7 5 0 - S

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

120

(

AGCY

)

1

60

9.0

1.08

NEMA

5-15

P

,

120

1

60

9.0

1.08

15A-125

V PLUG

208-240

(

AGCY

)

1

60

4.5

1.08

NEMA

6-15

P

,

at 208

1

60

3.9

.81

15A-250

V PLUG

at 240

1

60

4.5

1.08

(USA ONLY)

230

(

AGCY

)

1

50

4.3

1.0

CEE

7/7,

230

1

50

4.3

.99

220-230

V PLUG

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE

OF QUALIFIED SERVICE TECHNICIANS ONLY AND

IS NOT INTENDED FOR USE BY UNTRAINED OR

UNAUTHORIZED SERVICE PERSONNEL.