500-S, 750-S, 1000-S, 1000-UP • INSTALLATION/OPERATION/SERVICE MANUAL • 17.

O P E R A T I O N

Timer Programming Information

1. Turn On/Off Control Key OFF.

Press the On/Off Key until the display turns

OFF (at least 3 seconds) and On/Off Key's

Power Indicator Light goes out.

Note:

The following steps can only be done when

the On/Off Control Key is OFF.

2. Set Shelf Timer Keys.

Press and hold a Shelf Timer Key (at least

3 seconds) until the countdown time is shown

in the LED display. Use the Up or Down

Arrow Key to change the time desired.

Time will display as HH:MM if set for longer

than 60 minutes, or HH:SS if set for less than

60 minutes.

3. Set Additional Timer Keys.

Repeat step 2 for each Shelf Timer Key

to be programmed.

4. Turn On/Off Power Key ON.

Using the timer, press the On/Off key to

turn ON unit. Power Indicator Light

will illuminate.

5. Press Shelf Timer Key.

Activate the shelf timer by pressing the

corresponding button. Shelf LED display will

illuminate and the count down will begin.

The timer LED’s will illuminate as follows:

a) All expired timers will flash quickly (may be

more than one)

b) The timer with the shortest amount of time

remaining will flash slowly.

c) All other active timers will be illuminated

(may be more than one).

6. Turn OFF alarm.

Alarm will sound as time expires.

Press expired Shelf Timer Key to turn the

alarm OFF.

To Cancel a Timer:

Press and hold desired Shelf Timer Key for

two seconds.

Power Failure:

The Power Indicator Light

by On/Off Power Key will blink to indicate a

power failure. To stop the blinking, simply

depress On/Off Key. The memory will not

be impaired.

1

2

3

4

5

6

UP

/

DOWN

ARROWS

LOCK

INDICATOR

HEAT

INDICATOR

LIGHT

LED

DISPLAY

ON

/

OFF

KEY

POWER

INDICATOR

LIGHT

SHELF TIMER KEYS

The Multiple Shelf Timer Key option is available for

hot food holding units with the electronic control.

These keys monitor food safety by using a timer-

based "First-In, First-Out" product management

system. Products should be cooked to HACCP

recommended internal temperature and then held

in the unit. The Timer system allows operator to

select holding times when the unit is loaded.

Multiple timer keys correspond to various pan

locations in the holding unit. As the timers expire,

alarms notify the operator.

E L E C T R O N I C C O N T R O L T I M E R P R O G R A M M I N G

Advertising
This manual is related to the following products: