Alliance Laundry Systems CHM166C User Manual

Page 12

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation/Operation Supplement

F232145 (EN)

10

Table 3 (Continued)

Drive Train Information

Number of motors in drive train

1

1

1

1

1

1

1

1

Drive motor power, HP (kW)

2

(1.5)

2

(1.5)

2

(1.5)

2

(1.5)

2

(1.5)

3

(2.2)

5

(3.7)

7.5

(5.6)

Cylinder Speeds

Gentle wash/reverse speed, RPM

29

27

26

26

24

24

22

27

Wash/reverse speed, RPM

52

48

46

47

43

43

40

37

Distribution speed, RPM

82

86

73

73

68

77

63

62

Low extract speed, RPM

366

343

328

328

307

307

280

260

Medium extract speed, RPM
(Not available on Electronic Control models.)

534

500

478

478

447

447

408

380

High extract speed, RPM

685

641

613

614

573

574

524

485

Centrifugal Force Data

Gentle wash centrifugal force, Gs

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.43

Wash/reverse centrifugal force, Gs

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Distribution centrifugal force, Gs

2

2

2

2

2

2

2

2

Low extract centrifugal force, Gs

40

40

40

40

40

40

40

40

Medium extract centrifugal force, Gs

85

85

85

85

85

85

85

85

High extract centrifugal force, Gs

140

140

140

140

140

140

140

140

Balance Detection

Vibration switch installed*

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Direct Steam Heating (Optional)

Steam inlet connection size,
in. (mm)

1/2

(13)

1/2

(13)

1/2

(13)

1/2

(13)

1/2

(13)

1/2

(13)

1/2

(13)

3/4

(19)

Number of steam inlets

1

1

1

1

1

1

1

1

Steam required to raise bath water
temperature 10

°F (6°C), lbs. (kg)

LOW

0.62

(0.28)

0.92

(0.42)

2.1

(1.51)

2.09

(1.51)

2.8

(2.0)

3.6

(1.63)

4.1

(2.93)

6.8

(4.9)

HIGH

0.88

(0.4)

1.31

(0.6)

2.69

(1.96)

2.84

(2.04)

3.6

(2.59)

5.5

(2.49)

6.0

(4.34)

8.9

(6.4)

Average steam use per cycle, bhp (kg)

0.54

(8.3)

0.73

(11.3)

1.4

(21.6)

1.43

(22.4)

1.8

(28.9)

2.32

(36.4)

2.93

(45.9)

4.5

(71)

Electrical Heating (Optional)

Total electrical heating capacity, kW

7.8

7.8

15.6

15.6

23.4

23.4

31.2

N/A

Electrical heating elements

3

3

6

3

9

9

12

N/A

Electrical heat element size, kW

2.6

2.6

2.6

5.2

2.6

2.6

2.6

N/A

* Refer to Gap Setting for Vibration Switch (Variable-Speed and Fixed-Speed Models) section for specifications.