Alliance Laundry Systems CHM166C User Manual
Page 9
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
7
F232145 (EN)
Table 1 (Continued)
2 Speed Models (Continued)
Specification
18, 20
25
27, 30
35
40
50
60
Balance Detection
Vibration switch installed
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Direct Steam Heating (Optional)
Steam inlet connection size,
in. (mm)
1/2
(13)
1/2
(13)
1/2
(13)
1/2
(13)
1/2
(13)
1/2
(13)
1/2
(13)
Number of steam inlets
1
1
1
1
1
1
1
Steam required to raise
bath water temperature
10
°F (6°C)
LOW
1.05 (0.75)
1.4 (1.01)
1.44 (1.03) 2.06 (1.48) 2.09 (1.51) 2.76 (1.99) 2.76 (1.99)
HIGH
1.4 (1.01)
1.59 (1.15) 1.91 (1.37) 2.69 (1.94) 2.84 (2.04) 3.59 (2.59) 3.59 (2.59)
Average steam use per cycle,
bhp (kg)
0.71
(11.1)
0.87
(13.6)
0.97
(15.2)
1.4
(21.6)
1.43
(22.4)
1.84
(28.9)
1.84
(28.9)
Electrical Heating (Optional)
Total electrical heating capacity,
kW
7.8
7.8
7.8
15.6
15.6
23.4
23.4
Electrical heating elements
3
3
3
6
3
9
9
Electrical heat element size, kW
2.6
2.6
2.6
2.6
5.2
2.6
2.6