Insert installation, Insert size requirements (see illustration below), Insert placement requirements – Avalon Stoves Rainier User Manual

Page 18: Hearth requirements, Minimum clearances

Advertising
background image

18

Insert Installation

(for qualified installers only)

Travis Industries

100-01140

4 020628

Insert Size Requirements (see Illustration below)

Minimum Fireplace
S i z e

Masonry
Fireplace

Z.C. (Metal)
Fireplace

a

b

c

d

e

f

g

h

i

j

Height (front)

Height (rear)

Width (front)

Width (rear)

Depth Rainier-90

Depth Rainier-45

Hearth Rainier-90*

Hearth Rainier-45*

Hearth Width

Facing Width

Facing Height

with Mantel Shield

Mantel Height

with Mantel Shield

21 7/8"

21 7/8"

25 3/4"

25 3/4"

14 1/2"

9 1/2"

21 1/8"

26"

41 3/4"

51 3/4"

50 5/8"

35 5/8"

52 5/8"

37 5/8"

21 7/8"

21 7/8"

27 3/4"

27 3/4"

15 1/2"

10 1/2"

21 1/8"

26"

41 3/4"

49 3/4"

33 1/8"

N/A

45 1/8"

N/A

a

c

e

f

b

d

h

i

j

g

Non-Combustible Hearth

Combustible Mantel

Non-Combustible Facing

* This is the distance the insert protrudes from the
fireplace opening plus the required 16" of hearth
extension.

Insert Placement Requirements

•

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert

•

Insert and hearth must be installed on a level, secure floor

•

The minimum clearances, facing, and hearth requirements in the illustration below must be met
(follow the clearances for the type of fireplace being used - either masonry or zero-clearance).

Side

Wall

Combustible Mantel

Combustible Top Facing

Non-Combustible

Hearth

Facing

Masonry

Fireplace

Minimum Clearances

k

l
m

n

o

p

q

x

Sidewall to Insert

Side Facing
Top Facing

w. Mantel Shield

Mantel to Insert

w. Mantel Shield
Hearth (Front)*

Hearth (Side)

Front of Insert

Hearth Ext. Rainier-90

Hearth Ext. Rainier-45

14"

13"
29 1/2"

14 1/2"

31 1/2"

16 1/2"
16"

8"

36"

5 1/8"

10"

* Does not include the distance the insert

extends onto the hearth (dimension "x").

q

l

k

p

x

o

n

m

ZC (Metal)

Fireplace

30"

12"
12"

N/A

24"

N/A
16"

8"

36"

5 1/8"

10"

Hearth Requirements

•

Must extend 16" in front of the insert and 8" on both sides

•

Must be non-combustible 1/4" thick insulating board with a thermal conductivity of K = 0.72