Warning – Alliance Laundry Systems CABINET HARDMOUNT HC80VNV User Manual

Page 12

Advertising
background image

Programming

F232141

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming Setup Options

1. With display showing sump temperature, press

Stop (*) key to enter SETUP Mode.

2. Use Up or Down (arrow) key to scroll through

setup options. Refer to Table 1 for possible setup
options and description.

3. Press the Start (#) key to accept the option and to

then scroll forward to the next setup option.

4. Press the Stop (*) key anytime to exit SETUP

Mode. The display will show sump temperature.

Programming a Cycle

1. With the display showing sump temperature,

press the Up (arrow) key to edit a cycle. The
display will show “CY01”.

NOTE: On VNV and VN2 models, 26 of the
30 cycles available are pre-programmed.

2. Press Up or Down (arrow) key until cycle to be

edited is displayed. The display will show
“CY01”. Press Start (#) key to begin editing
selected cycle.

3. Use Up or Down (arrow) key to select agitation

action. Refer to Table 2 for agitation action
options. Press Start (#) key.

NOTE: This action applies to entire cycle.

4. On VNV models only, use Up or Down (arrow)

key to select agitation speed: normal (“AGSn”)
or gentle (“AGSL”). Press Start (#) key.

5. Use Up or Down (arrow) key to select next

option: “PUnP” or “nPnP”. This is for a future
recirculation feature. It has no effect on wash
cycle. Select “nPnP” and press Start (#) key.

Setup Options

Description

FAr

”/“

CEL

Select

FAr

”: degrees are displayed

in Fahrenheit.
Select

CEL

”: degrees are

displayed in Celsius.

noHt

”/“

HEAT

Select “noHt”: no heat is available
during a cycle regardless of
programmed temperature setting.
Select “HEAT”: heat is available as
long as a temperature is
programmed.

SUP5

”/“

AFIL

Select

SUP5

”: a fifth or sixth

supply can be programmed in a
cycle step.
Select

AFIL

”: auxiliary fills can

be programmed to low, medium or
high water level in a cycle step.

tFIL

”/“

ntFL

Select

tFIL

”: a temperature-

controlled fill can be programmed
for any segment. Select “ntFL”:
feature is disabled.

COOL

”/“

noCL

Select

COOL

”: automatic cool-

down feature is enabled allowing
cold water to flush into wash before
a drain if temperature is 140ºF or
above.
Select

noCL

”: feature is disabled.

Table 1

To prevent personal injury, avoid contact
with inlet water temperatures higher than
125
° Fahrenheit (51° Celsius) and hot
surfaces.

W748

WARNING

Agitation Action Options

Display

Description Percentage

AG 1

27 seconds forward,

3 seconds pause,

27 seconds reverse,

3 seconds pause

90%

AG 2

10 seconds forward,

20 seconds pause,

10 seconds reverse,

20 seconds pause

33%

AG 3

3 seconds forward,

27 seconds pause,

3 seconds reverse,

27 seconds pause

10%

AG 4

4 seconds forward,

56 seconds pause,

4 seconds reverse,

56 seconds pause

6.7%

Table 2

Advertising
This manual is related to the following products: