Programming Cycle Segments

NOTE: Each cycle program can be customized
within the 11 program segments contained in a
cycle. A time must be entered for each segment. To
skip a segment or spin, set the time to “

00” and

press Start (#) key. Refer to Table 3 for time
parameters.

NOTE: Spin times in cycle segments 1 – 10 are
entered in seconds (30 to 240), and time for final
spin in segment 11 is entered in minutes (1 to 10).

6. Press Up (arrow) key until display shows

segment to be edited. Press Start (#) key.

7. Use Up or Down (arrow) key to select Segment

Time. Set this value to “00” to skip segment.
Press Start (#) key.

8. If Temperature-Controlled Fill Setup Option is

enabled, display will show “tFIL”. Press
Start (#) key.

9. Use Up or Down (arrow) key to select Fill

Temperature: Cold (“CFIL”), Hot (“HFIL”),
Warm (“bFIL”) or Auxiliary (“AFIL”). Press
Start (#) key.

NOTE: An auxiliary fill is available only if

SUP5”/“AFIL” setup option is set to “AFIL”.

10. Use Up or Down (arrow) key to select Fill Level:

Low (“Lo”), Medium (“nEd”) or High (“HI”).
Press Start (#) key.

11. Use Up or Down (arrow) key to select Supply

Option. Refer to Table 4.

12. Press Start (#) key.

13. Use Up or Down (arrow) key to select Segment

Temperature: 75

° to 200°F or 25° to 93°C

.

Set

this value to zero to disable auxiliary heat and
temperature-controlled fill. Press Start (#) key.

NOTE: Only available if Temperature-Controlled
Fill or Auxiliary Heat Setup Option is enabled.

Time Parameters

Segment

Minimum

Maximum

PreWash “

PrE

2 minutes

30 minutes

Wash “

UASH

2 minutes

20 minutes

Fill 1 – Fill 9

FIL1

”... “

FIL9

2 minutes

15 minutes

Intermediate Spin

30 seconds

240 seconds

Final Spin

1 minute

10 minutes

Table 3

Supply Options

Display

Supply

SUP0

No Supply

SUP1

Supply 1

SUP2

Supply 2

SUP3

Supply 3

SUP4

Supply 4

SUP5

Supply 5*

SUP6

Supply 1 and 5*

SUP7

Supply 3 and 4

*This is available only if the “

SUP5

”/“

AFIL

” setup

option is set to “

SUP5

”.

Table 4

To prevent personal injury, avoid contact
with inlet water temperatures higher than
125
° Fahrenheit (51° Celsius) and hot
surfaces.

W748