4. table of thermistor characteristics, Service procedures – Panasonic 36PSU1U6 User Manual

Page 178

Advertising
background image

4-14

4. Service procedures

Check Pin
Short-circuit the cooling check pin (or heating check pin) on the outdoor unit control PCB to perform the control
described below.

1. Thermistor checks

The checks listed below are performed for 1 second each, in order from the top down. The results are displayed
by LED 1 and 2.

Discharge temp. (TD)

Outdoor air temp. ( TO)

Heat exchanger temp. (C1)

Heat exchanger temp. (C2)

Intake temp. (TS)

Thermistor

Check results

Normal

Abnormal

LED 1 and 2 OFF

LED 1 lit

LED 1 lit

LED 1 lit

LED 2 lit

2. 4-way valve turns ON for 1 second.

3. Forced cooling (or heating) operation

4-4. Table of Thermistor Characteristics

(1) Outdoor Air Temp. (TO), Intake Temp. (TS), Heat

Exchanger Temp. (C1) Sensor, Heat Exchanger
Temp. (C2) Sensor

(2) Discharge Temp. (TD) Sensors

Temperature (˚F)

Resistance (k

)

Temperature (

°F)

Resistance (k

)

4

SM830203-01_PAC-i_US-letter.indb14 14

SM830203-01_PAC-i_US-letter.indb14 14

2012/01/26 10:32:04

2012/01/26 10:32:04

Advertising
This manual is related to the following products: