Caution, Replacing belt – Panasonic MC-UL815 User Manual

Page 48

Advertising
background image

Replacing Belt

Side Latch

Loquet latéral
Pestillo laterale

Nozzle Cover

Couvercle de la
tête d'aspiration
Cubierta de la boquilla

Rear Latch

Loquet arrière
Pestillo trasero

Side Latch

Loquet latéral
Pestillo laterale

Belt

Correa

Courroie

Agitator

Agitateur
Agitador

End Cap

Tapa del
extremo

Bouchon

Motor Shaft

Eje del motor

Arbre du moteur

Belt Groove

Rainure de
la courroie
Polea para
correa

Belt Guide

Guía para la
correa

Glissière de
la courroie

Replace belt whenever a burning

rubber smell caused by excessive
slippage occurs.

Turn off and unplug the vacuum

cleaner.

Push in rear nozzle latch.

Press side latches towards back of

nozzle and rotate cover from nozzle.

Remove agitator by carefully lifting

out.

Remove worn or broken belt.

Clean agitator and the end caps.

Loop new belt (part number

MC-V380B) around motor shaft and
agitator belt groove. Make sure belt
is routed in the belt guide as shown.
See illustration for correct belt
routing.

Reinstall agitator back into nozzle by

placing end caps into grooves.

After reinstalling the agitator, turn it

by hand to make sure that belt is not
twisted or pinched and that all
rotating parts turn freely.

Reinstall nozzle cover by aligning

front edge of the cover with the
nozzle and rotating. Ensure rear
latch and side latches are locked into
slots by pressing firmly.

CAUTION

Motor shaft may be hot.

- 48 -

Advertising