Panasonic FV-05VFL2 User Manual

Page 4

Advertising
background image

Specifications are based on HVI standard.

Unpack and carefully remove unit from carton.
Refer to the Supplied Accessories list to verify that all parts are present.

1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).

o

o

2. Make certain that the electric service supply voltage is 120V, 60 Hz.

3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and

the Occupation Safety and Health Act (OSHA).

4. Always disconnect the power source before working on or near the fan, motor or light fixture.

5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.

6. Do not kink the power cord.

7. Do not install the unit where ducts are configured as shown in Fig. A.

8. Provide suction parts with proper ventilation.

9. This unit is approved for use over a bathtub or shower when installed in a GFCI protected

branch circuit.

Adaptor

Fig. A

Noise
(sone)

Duct

diameter

(inches)

4
3
4
3
4
3

36

36

36

11.0

.0

11.0 (5.0)

11.0 (5.0)

(5 )

FV-05VFL2

FV-08VFL2

FV-11VFL2

4

4

4

<0.3
<0.3

0.5
0.6
1.3
1.5

16
15
30
30
33
33

700
760
830
940
910

1050

50
50
80
70

110

90

(cfm)