Diagnostics – parking light flash table, P. 18 user guide, Flashes description – Autostart AS-6450VTW-FM User Manual

Page 18

Advertising
background image

P. 18 User

Guide

Diagnostics – Parking Light Flash Table

Flashes

Description

1

•

Doors locked, alarm and starter kill armed

•

Run time has expired

•

TRUNK

button pressed

•

Start signal received by the module

•

Cold weather mode cancelled

2

•

Remote start attempt cancelled by remote

•

Doors unlocked, starter kill disarmed

•

Exiting ignition valet

•

Power ON to OFF (automatic transmission)

•

Exiting remote valet

•

Power-up reset

•

Board set from manual to automatic; power

ON

2 slow flashes then

8 quick flashes

•

Reset from manual to automatic

3

• Entering ignition valet

• Entering or exiting ready mode

•

Entering remote valet

•

Entering extended run time

4

•

+12 V detected on the brake input wire

either while cranking or during run time

•

Entering multi-speed tach programming

• Board set from automatic to manual; power

ON

• Power ON to OFF ( manual transmission)

5 Fast

•

Tach signal programmed

•

New transmitter programmed

6

•

A remote start was attempted while a tach-before-crank signal was detected before cranking

8

•

Unit reset

10

•

A ground (-) signal was detected on the hood pin input wire wire when attempting to remote start

or during run time

When pressing

START/STOP

15 quick flashes

•

The parking brake is connected to ground (automatic transmission)

1 – pause – 2

•

There was a remote start attempt while the vehicle was in valet mode

•

Failed start: vehicle’s low battery voltage

…followed by 1 flash

•

Exiting cold weather mode

ON SOLID for 3

seconds….

…followed by 3 flashes

•

Entering cold weather mode

ON continuously

•

Idle mode: Idle mode is engaged

•

Run time: The vehicle has been remote started and is in run time.

ON 2 seconds

•

The hood has been opened and a ground (-) signal has been detected on the hood pin input

wire

ON 4 seconds

•

Locking or unlocking a door (with door pulses configured to 4 sec.)

ON 20 seconds

•

The hood pin has been flashed and you now have access to the programming options

Constant flashes

up to 60 sec.

•

In siren or horn mode: Alarm condition generated by an intrusion, by panic mode or when the

system is powered up