9.2.11 Pump head
 
 
 
 
Disconnect the pump wires from the controller (see note in § 9.2.1).
Undo two Allen bolts on the Wilo pump head (alternative pump 
Grundfos has 4 Allen bolts) to remove the pump head from the body. 
Fit replacement pump head in reverse order. The pump must be 
vented via its vent plug after refilling the appliance. 
9.2.12 Expansion vessel
Unscrew the flexible hose connection, making sure that the sealing 
ring is not damaged. Unclip the bracket holding the vessel and fit 
replacement including the sealing ring. Using the Schroeder valve on 
the expansion vessel, and pump if required, check the pressure is 1 
bar. 
 
 