152-388-100-02, Issue 2

Monitoring System Activity and Performance

H2TU-C-388 List 1

June 6, 2000

33

Alarm History at the HDSL2 Interface

Figure 23

shows the H2TU-C HDSL2 alarm history, and

Table 12

describes the alarms.

Figure 23.

H2TU-C HDSL2 Alarm History Screen

Table 12.

HDSL2 Alarm Descriptions

Screen Alarm

Front-Panel Alarm Description

HDSL2 ALARMS at the H2TU-C and H2TU-R

LOSW

LOSW

Loss of Sync Word—The HDSL2 loop has lost synchronization.

MAL

MAL

Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value
set for the system.

LA

LA

Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold.

HBER

HBER

Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of
10

-6

or 10

- 7

.

HDSL2 ALARMS at the H2TU-C only

SHORT

PWR FEED SHRT

Indicates a short between the Tip and Ring of the HDSL2 pair.

GND

PWR FEED GND

The HDSL2 loop is grounded.

OPEN

PWR FEED OPEN

Indicates a line power open condition.

Monitor

Performance

Event Log

Config

Inventory

Rlogon

Help

H2TU-C HDSL2 Alarm History

------------------------------------------------------------------------------

Alarm

First

Last

Status

Count

LOSW

04/03/00 00:00

04/03/00 00:45

ALARM

12

MAL

OK

0

LA

OK

0

HBER

04/03/00 00:37

04/03/00 00:45

OK

7

SHORT

OK

0

GND

OK

0

OPEN

OK

0

Press: C(l)ear Alarm History

------------------------------------------------------------------------------

Press <Space> to cycle through

Interface

: H2TU-C HDSL2

choices and <Enter> to view

Statistics :

Alarm History

ID: xxxx--xxxx--xxxx--xxxx

04/15/00 12:30:01

H2TU-C

System: Alarm